A-2 Preliminary November 23, 1998 MultiVoice Gateway for the MAX— User’s Guide
Troubleshooting
LEDs
Table A-1 lists and describes each LED.
Figure A-2 shows the location of the LEDs on the front panel of the Redundant MultiVoice
Gateway.
Figure A-2. Location of LEDs on the Redundant MultiVoice Gateway
Table A-1. MultiVoice Gateway front-panel LEDs
LED Description
Power On when the MultiVoice Gateway power is on.
Fault On in one of two cases: either a hardware self-test is in progress or there is a
hardware failure.
When a hardware self-test is in progress, the LED stays on. If any type of
hardware failure occurs, the LED flashes. If the failure is isolated to a
expansion card, the MultiVoice Gateway might continue to function without
the expansion card.
Data On when calls are active.
Alarm On when there is a WAN alarm or when a trunk is out of service, such as
during line loopback diagnostics.
WAN alarms include Loss of Sync, Red Alarm, Yellow Alarm, and All Ones
(or AIS).